From: MXene sensors based on optical and electrical sensing signals: from biological, chemical, and physical sensing to emerging intelligent and bionic devices

Fig. 11

a Schematic diagram of photothermal testing of MXene sample under a xenon lamp [202]. b Temperature changes of MXene sample with the xenon lamp on and off (power density = 100 mW/cm2) [202]. c Changes in temperature and relative resistance during heating and cooling of MXene sample [202]. Copyright 2021, Elsevier. d Real-time changes in temperature under different input voltages [203]. e Stable changes in temperature when the input voltage is repeatedly turned on and off [203]. Copyright 2020, American Chemical Society. f The relative resistance of MXene sample changes under different temperature environments [204]. Copyright 2019, Royal Society of Chemistry. g SEM images of the MXene/CCS@CF [205]. h Voltage-current curve of the MXene/CCS@CF [205]. i Real-time temperature changes of MXene/CCS@CF with different input voltages [205]. j Infrared camera images of MXene/CCS@CF after heating and cooling [205]. Copyright 2021, American Chemical Society