Table 1 The single LG mode operation achieved with different lenses (L2)

From: Intracavity spherical aberration for selective generation of single-transverse-mode Laguerre-Gaussian output with order up to 95

Focal length

Shape

Pump power

Radial indices p

Angular indices m

Range of δ

Output power range

15.3 mm

Plano-Convex

1.03 W

0

1–5

0.20–0.37 mm

10–57 mW

25.4 mm

Plano-Convex

1.03 W

0–4

2–16

0.70–1.23 mm

123–155 mW

33.9 mm

Plano-Convex

1.03 W

0

10–33

1.30–1.80 mm

18–191 mW

51.8 mm

Bi-Convex

1.03 W

0

27–75

4.42–5.14 mm

11–124 mW

1.20 W

0

32–95

4.50–5.60 mm

2–132 mW